GF + STERILINE - Complete Line - VFCSM 10000 + AFM 12000 + ST 0 + GFWM6

orCall +39 051 4086204

Specifications

ManufacturerGF + STERILINE
ModelVFCSM 10000 + AFM 12000 + ST 0 + GFWM6
Year2009
ConditionUsed
Serial NumberMLTC-10_24-1494_24-1493_24-1492_24-1491

Description

COMPLETE FILLING/CLEANING/STERILIZATION LINE GF/STERILINE


consisting of



1) FILLING/CAPPING MACHINE STERILE GF, MODEL VFCSM 10000

Year of construction: 2009


User interface of the machine on the front of the machine, which also contains the machine control and monitoring commands.



  • Carrying base
  • Independently operated belt for container feeding
  • Filling station (4 nozzles to fill 2 containers simultaneously, for 2 consecutive doses) operated directly by the main motor of the machine
  • Dosing unit for filling (distributor for the filling liquid + 2 nozzles connected to the filling station)
  • Capping station, operated directly by the main motor of the machine, composed of 2 capping heads that allow the machine to pick up the caps and place them on the container


  • Containers deemed suitable for the required quality standards are deposited on the output belt, while those not suitable are directed into the appropriate drawer



ELECTRICAL CHARACTERISTICS


  • Main power supply: 380 V - 50 Hz - 3F + N
  • Installed electrical power: 5kw
  • Auxiliary power supply: 24 V
  • Operating pressure: 6 bar



2) GF STERILE FILLERS, MODEL AFM 12000

Year of construction: 2009



PRODUCTION CHARACTERISTICS

  • Maximum speed: 12,000 containers/h



OPERATION CHARACTERISTICS

Nitrogen washing stations

  • 2 nitrogen supply manifolds, and special needles for introducing gas into containers

Filling station

  • 6 syringes for product distribution and 6 filling nozzles

Sealing stations

  • 1 container preheating unit and a sealing unit, both using burners powered by high-pressure oxygen



ENERGY CONSUMPTION

  • Main power supply: 380 V ac - 50 Hz - 3 F + n
  • Auxiliary power supply: 24 v
  • Installed electrical power: 3 kw
  • Working pressure: 6 bar



3) STERILINE AUTOCLAVE, MODEL ST 0

Year of construction: 2009



INLET CHAMBER

  • upper volume (inlet fan, exhaust fan, pre-filter and HEPA filter)
  • filter periphery (vacuum, connected to the air exhaust area)
  • intermediate volume (transport system, tunnel inlet door with its motor and potentiometer)

Access to the three volumes is provided by removable panels for cleaning and maintenance



HOT CHAMBER

  • the hot chamber consists of two boxes, one inside the other, thermally insulated and the air is recirculated. The two boxes are separated by a layer of insulating material with a minimum thickness of 120 mm and a maximum of 150 mm
  • the inner box can be heated up to 400°C
  • a door on the right side, filled with insulation material, gives access to the filter area, fan and heating elements
  • the fan motor is located outside the chamber, above the tunnel roof



COOLING CHAMBER

  • in the upper volume there is the fan and the HEPA filter
  • on the roof there is the balancing fan that connects the cooling chamber to the intake area of ​​the supply fan of the inlet chamber
  • in the intermediate volume there is the cooling battery
  • the water supply to the battery is regulated by a solenoid valve




4) WASHING MACHINE FOR GF VIALS AND BOTTLES, MODEL GFWM6

Year of construction: 2009



  • single operator panel from which it is possible to carry out all the operations necessary for the operation and management of the machine
  • washing product supply circuit
  • washing carousel made of stainless steel, contains the clamps for transporting the containers and the washing nozzles
  • container unloading
  • single electrical panel, which includes all the control components for operation



PRODUCTION CHARACTERISTICS


  • Maximum speed: 18,000 containers/h (reference: 1 ml vials. The production speed can be varied by acting on the control panel)



ENERGY CONSUMPTION


  • Main power supply: 380 v - 50 Hz - 3F + N
  • Auxiliary power supply: 24 v
  • Total: 8 kw
  • Working pressure: 0.7 / 0.8 MPA